e46d3b 1 <?xml version="1.0"?>
2 <doc>
3     <assembly>
4         <name>EasyModbus</name>
5     </assembly>
6     <members>
7         <member name="T:EasyModbus.ModbusClient">
8             <summary>
9             Implements a ModbusClient.
10             </summary>
11         </member>
12         <member name="M:EasyModbus.ModbusClient.#ctor(System.String,System.Int32)">
13             <summary>
14             Constructor which determines the Master ip-address and the Master Port.
15             </summary>
16             <param name="ipAddress">IP-Address of the Master device</param>
17             <param name="port">Listening port of the Master device (should be 502)</param>
18         </member>
19         <member name="M:EasyModbus.ModbusClient.#ctor(System.String)">
20             <summary>
21             Constructor which determines the Serial-Port
22             </summary>
23             <param name="serialPort">Serial-Port Name e.G. "COM1"</param>
24         </member>
25         <member name="M:EasyModbus.ModbusClient.#ctor">
26             <summary>
27             Parameterless constructor
28             </summary>
29         </member>
30         <member name="M:EasyModbus.ModbusClient.Connect">
31             <summary>
32             Establish connection to Master device in case of Modbus TCP. Opens COM-Port in case of Modbus RTU
33             </summary>
34         </member>
35         <member name="M:EasyModbus.ModbusClient.Connect(System.String,System.Int32)">
36             <summary>
37             Establish connection to Master device in case of Modbus TCP.
38             </summary>
39         </member>
40         <member name="M:EasyModbus.ModbusClient.ConvertRegistersToFloat(System.Int32[])">
41             <summary>
42             Converts two ModbusRegisters to Float - Example: EasyModbus.ModbusClient.ConvertRegistersToFloat(modbusClient.ReadHoldingRegisters(19,2))
43             </summary>
44             <param name="registers">Two Register values received from Modbus</param>
45             <returns>Connected float value</returns>
46         </member>
47         <member name="M:EasyModbus.ModbusClient.ConvertRegistersToFloat(System.Int32[],EasyModbus.ModbusClient.RegisterOrder)">
48             <summary>
49             Converts two ModbusRegisters to Float, Registers can by swapped
50             </summary>
51             <param name="registers">Two Register values received from Modbus</param>
52             <param name="registerOrder">Desired Word Order (Low Register first or High Register first</param>
53             <returns>Connected float value</returns>
54         </member>
55         <member name="M:EasyModbus.ModbusClient.ConvertRegistersToInt(System.Int32[])">
56             <summary>
57             Converts two ModbusRegisters to 32 Bit Integer value
58             </summary>
59             <param name="registers">Two Register values received from Modbus</param>
60             <returns>Connected 32 Bit Integer value</returns>
61         </member>
62         <member name="M:EasyModbus.ModbusClient.ConvertRegistersToInt(System.Int32[],EasyModbus.ModbusClient.RegisterOrder)">
63             <summary>
64             Converts two ModbusRegisters to 32 Bit Integer Value - Registers can be swapped
65             </summary>
66             <param name="registers">Two Register values received from Modbus</param>
67             <param name="registerOrder">Desired Word Order (Low Register first or High Register first</param>
68             <returns>Connecteds 32 Bit Integer value</returns>
69         </member>
70         <member name="M:EasyModbus.ModbusClient.ConvertRegistersToLong(System.Int32[])">
71             <summary>
72             Convert four 16 Bit Registers to 64 Bit Integer value Register Order "LowHigh": Reg0: Low Word.....Reg3: High Word, "HighLow": Reg0: High Word.....Reg3: Low Word
73             </summary>
74             <param name="registers">four Register values received from Modbus</param>
75             <returns>64 bit value</returns>
76         </member>
77         <member name="M:EasyModbus.ModbusClient.ConvertRegistersToLong(System.Int32[],EasyModbus.ModbusClient.RegisterOrder)">
78             <summary>
79             Convert four 16 Bit Registers to 64 Bit Integer value - Registers can be swapped
80             </summary>
81             <param name="registers">four Register values received from Modbus</param>
82             <param name="registerOrder">Desired Word Order (Low Register first or High Register first</param>
83             <returns>Connected 64 Bit Integer value</returns>
84         </member>
85         <member name="M:EasyModbus.ModbusClient.ConvertRegistersToDouble(System.Int32[])">
86             <summary>
87             Convert four 16 Bit Registers to 64 Bit double prec. value Register Order "LowHigh": Reg0: Low Word.....Reg3: High Word, "HighLow": Reg0: High Word.....Reg3: Low Word
88             </summary>
89             <param name="registers">four Register values received from Modbus</param>
90             <returns>64 bit value</returns>
91         </member>
92         <member name="M:EasyModbus.ModbusClient.ConvertRegistersToDouble(System.Int32[],EasyModbus.ModbusClient.RegisterOrder)">
93             <summary>
94             Convert four 16 Bit Registers to 64 Bit double prec. value - Registers can be swapped
95             </summary>
96             <param name="registers">four Register values received from Modbus</param>
97             <param name="registerOrder">Desired Word Order (Low Register first or High Register first</param>
98             <returns>Connected double prec. float value</returns>
99         </member>
100         <member name="M:EasyModbus.ModbusClient.ConvertFloatToRegisters(System.Single)">
101             <summary>
102             Converts float to two ModbusRegisters - Example:  modbusClient.WriteMultipleRegisters(24, EasyModbus.ModbusClient.ConvertFloatToTwoRegisters((float)1.22));
103             </summary>
104             <param name="floatValue">Float value which has to be converted into two registers</param>
105             <returns>Register values</returns>
106         </member>
107         <member name="M:EasyModbus.ModbusClient.ConvertFloatToRegisters(System.Single,EasyModbus.ModbusClient.RegisterOrder)">
108             <summary>
109             Converts float to two ModbusRegisters Registers - Registers can be swapped
110             </summary>
111             <param name="floatValue">Float value which has to be converted into two registers</param>
112             <param name="registerOrder">Desired Word Order (Low Register first or High Register first</param>
113             <returns>Register values</returns>
114         </member>
115         <member name="M:EasyModbus.ModbusClient.ConvertIntToRegisters(System.Int32)">
116             <summary>
117             Converts 32 Bit Value to two ModbusRegisters
118             </summary>
119             <param name="intValue">Int value which has to be converted into two registers</param>
120             <returns>Register values</returns>
121         </member>
122         <member name="M:EasyModbus.ModbusClient.ConvertIntToRegisters(System.Int32,EasyModbus.ModbusClient.RegisterOrder)">
123             <summary>
124             Converts 32 Bit Value to two ModbusRegisters Registers - Registers can be swapped
125             </summary>
126             <param name="intValue">Double value which has to be converted into two registers</param>
127             <param name="registerOrder">Desired Word Order (Low Register first or High Register first</param>
128             <returns>Register values</returns>
129         </member>
130         <member name="M:EasyModbus.ModbusClient.ConvertLongToRegisters(System.Int64)">
131             <summary>
132             Converts 64 Bit Value to four ModbusRegisters
133             </summary>
134             <param name="longValue">long value which has to be converted into four registers</param>
135             <returns>Register values</returns>
136         </member>
137         <member name="M:EasyModbus.ModbusClient.ConvertLongToRegisters(System.Int64,EasyModbus.ModbusClient.RegisterOrder)">
138             <summary>
139             Converts 64 Bit Value to four ModbusRegisters - Registers can be swapped
140             </summary>
141             <param name="longValue">long value which has to be converted into four registers</param>
142             <param name="registerOrder">Desired Word Order (Low Register first or High Register first</param>
143             <returns>Register values</returns>
144         </member>
145         <member name="M:EasyModbus.ModbusClient.ConvertDoubleToRegisters(System.Double)">
146             <summary>
147             Converts 64 Bit double prec Value to four ModbusRegisters
148             </summary>
149             <param name="doubleValue">double value which has to be converted into four registers</param>
150             <returns>Register values</returns>
151         </member>
152         <member name="M:EasyModbus.ModbusClient.ConvertDoubleToRegisters(System.Double,EasyModbus.ModbusClient.RegisterOrder)">
153             <summary>
154             Converts 64 Bit double prec. Value to four ModbusRegisters - Registers can be swapped
155             </summary>
156             <param name="doubleValue">double value which has to be converted into four registers</param>
157             <param name="registerOrder">Desired Word Order (Low Register first or High Register first</param>
158             <returns>Register values</returns>
159         </member>
160         <member name="M:EasyModbus.ModbusClient.ConvertRegistersToString(System.Int32[],System.Int32,System.Int32)">
161             <summary>
162             Converts 16 - Bit Register values to String
163             </summary>
164             <param name="registers">Register array received via Modbus</param>
165             <param name="offset">First Register containing the String to convert</param>
166             <param name="stringLength">number of characters in String (must be even)</param>
167             <returns>Converted String</returns>
168         </member>
169         <member name="M:EasyModbus.ModbusClient.ConvertStringToRegisters(System.String)">
170             <summary>
171             Converts a String to 16 - Bit Registers
172             </summary>
173             <param name="registers">Register array received via Modbus</param>
174             <returns>Converted String</returns>
175         </member>
176         <member name="M:EasyModbus.ModbusClient.calculateCRC(System.Byte[],System.UInt16,System.Int32)">
177             <summary>
178             Calculates the CRC16 for Modbus-RTU
179             </summary>
180             <param name="data">Byte buffer to send</param>
181             <param name="numberOfBytes">Number of bytes to calculate CRC</param>
182             <param name="startByte">First byte in buffer to start calculating CRC</param>
183         </member>
184         <member name="M:EasyModbus.ModbusClient.ReadDiscreteInputs(System.Int32,System.Int32)">
185             <summary>
186             Read Discrete Inputs from Server device (FC2).
187             </summary>
188             <param name="startingAddress">First discrete input to read</param>
189             <param name="quantity">Number of discrete Inputs to read</param>
190             <returns>Boolean Array which contains the discrete Inputs</returns>
191         </member>
192         <member name="M:EasyModbus.ModbusClient.ReadCoils(System.Int32,System.Int32)">
193             <summary>
194             Read Coils from Server device (FC1).
195             </summary>
196             <param name="startingAddress">First coil to read</param>
197             <param name="quantity">Numer of coils to read</param>
198             <returns>Boolean Array which contains the coils</returns>
199         </member>
200         <member name="M:EasyModbus.ModbusClient.ReadHoldingRegisters(System.Int32,System.Int32)">
201             <summary>
202             Read Holding Registers from Master device (FC3).
203             </summary>
204             <param name="startingAddress">First holding register to be read</param>
205             <param name="quantity">Number of holding registers to be read</param>
206             <returns>Int Array which contains the holding registers</returns>
207         </member>
208         <member name="M:EasyModbus.ModbusClient.ReadInputRegisters(System.Int32,System.Int32)">
209             <summary>
210             Read Input Registers from Master device (FC4).
211             </summary>
212             <param name="startingAddress">First input register to be read</param>
213             <param name="quantity">Number of input registers to be read</param>
214             <returns>Int Array which contains the input registers</returns>
215         </member>
216         <member name="M:EasyModbus.ModbusClient.WriteSingleCoil(System.Int32,System.Boolean)">
217             <summary>
218             Write single Coil to Master device (FC5).
219             </summary>
220             <param name="startingAddress">Coil to be written</param>
221             <param name="value">Coil Value to be written</param>
222         </member>
223         <member name="M:EasyModbus.ModbusClient.WriteSingleRegister(System.Int32,System.Int32)">
224             <summary>
225             Write single Register to Master device (FC6).
226             </summary>
227             <param name="startingAddress">Register to be written</param>
228             <param name="value">Register Value to be written</param>
229         </member>
230         <member name="M:EasyModbus.ModbusClient.WriteMultipleCoils(System.Int32,System.Boolean[])">
231             <summary>
232             Write multiple coils to Master device (FC15).
233             </summary>
234             <param name="startingAddress">First coil to be written</param>
235             <param name="values">Coil Values to be written</param>
236         </member>
237         <member name="M:EasyModbus.ModbusClient.WriteMultipleRegisters(System.Int32,System.Int32[])">
238             <summary>
239             Write multiple registers to Master device (FC16).
240             </summary>
241             <param name="startingAddress">First register to be written</param>
242             <param name="values">register Values to be written</param>
243         </member>
244         <member name="M:EasyModbus.ModbusClient.ReadWriteMultipleRegisters(System.Int32,System.Int32,System.Int32,System.Int32[])">
245             <summary>
246             Read/Write Multiple Registers (FC23).
247             </summary>
248             <param name="startingAddressRead">First input register to read</param>
249             <param name="quantityRead">Number of input registers to read</param>
250             <param name="startingAddressWrite">First input register to write</param>
251             <param name="values">Values to write</param>
252             <returns>Int Array which contains the Holding registers</returns>
253         </member>
254         <member name="M:EasyModbus.ModbusClient.Disconnect">
255             <summary>
256             Close connection to Master Device.
257             </summary>
258         </member>
259         <member name="M:EasyModbus.ModbusClient.Finalize">
260             <summary>
261             Destructor - Close connection to Master Device.
262             </summary>
263         </member>
264         <member name="P:EasyModbus.ModbusClient.Connected">
265             <summary>
266             Returns "TRUE" if Client is connected to Server and "FALSE" if not. In case of Modbus RTU returns if COM-Port is opened
267             </summary>
268         </member>
269         <member name="P:EasyModbus.ModbusClient.IPAddress">
270             <summary>
271             Gets or Sets the IP-Address of the Server.
272             </summary>
273         </member>
274         <member name="P:EasyModbus.ModbusClient.Port">
275             <summary>
276             Gets or Sets the Port were the Modbus-TCP Server is reachable (Standard is 502).
277             </summary>
278         </member>
279         <member name="P:EasyModbus.ModbusClient.UDPFlag">
280             <summary>
281             Gets or Sets the UDP-Flag to activate Modbus UDP.
282             </summary>
283         </member>
284         <member name="P:EasyModbus.ModbusClient.UnitIdentifier">
285             <summary>
286             Gets or Sets the Unit identifier in case of serial connection (Default = 0)
287             </summary>
288         </member>
289         <member name="P:EasyModbus.ModbusClient.Baudrate">
290             <summary>
291             Gets or Sets the Baudrate for serial connection (Default = 9600)
292             </summary>
293         </member>
294         <member name="P:EasyModbus.ModbusClient.Parity">
295             <summary>
296             Gets or Sets the of Parity in case of serial connection
297             </summary>
298         </member>
299         <member name="P:EasyModbus.ModbusClient.StopBits">
300             <summary>
301             Gets or Sets the number of stopbits in case of serial connection
302             </summary>
303         </member>
304         <member name="P:EasyModbus.ModbusClient.ConnectionTimeout">
305             <summary>
306             Gets or Sets the connection Timeout in case of ModbusTCP connection
307             </summary>
308         </member>
309         <member name="P:EasyModbus.ModbusClient.SerialPort">
310             <summary>
311             Gets or Sets the serial Port
312             </summary>
313         </member>
314         <member name="P:EasyModbus.ModbusClient.LogFileFilename">
315             <summary>
316             Gets or Sets the Filename for the LogFile
317             </summary>
318         </member>
319         <member name="T:EasyModbus.Exceptions.SerialPortNotOpenedException">
320             <summary>
321             Exception to be thrown if serial port is not opened
322             </summary>
323         </member>
324         <member name="T:EasyModbus.Exceptions.ConnectionException">
325             <summary>
326             Exception to be thrown if Connection to Modbus device failed
327             </summary>
328         </member>
329         <member name="T:EasyModbus.Exceptions.FunctionCodeNotSupportedException">
330             <summary>
331             Exception to be thrown if Modbus Server returns error code "Function code not supported"
332             </summary>
333         </member>
334         <member name="T:EasyModbus.Exceptions.QuantityInvalidException">
335             <summary>
336             Exception to be thrown if Modbus Server returns error code "quantity invalid"
337             </summary>
338         </member>
339         <member name="T:EasyModbus.Exceptions.StartingAddressInvalidException">
340             <summary>
341             Exception to be thrown if Modbus Server returns error code "starting adddress and quantity invalid"
342             </summary>
343         </member>
344         <member name="T:EasyModbus.Exceptions.ModbusException">
345             <summary>
346             Exception to be thrown if Modbus Server returns error code "Function Code not executed (0x04)"
347             </summary>
348         </member>
349         <member name="T:EasyModbus.Exceptions.CRCCheckFailedException">
350             <summary>
351             Exception to be thrown if CRC Check failed
352             </summary>
353         </member>
354         <member name="T:EasyModbus.ModbusProtocol">
355             <summary>
356             Modbus Protocol informations.
357             </summary>
358         </member>
359         <member name="P:EasyModbus.TCPHandler.LocalIPAddress">
360             When making a server TCP listen socket, will listen to this IP address.
361         </member>
362         <member name="M:EasyModbus.TCPHandler.#ctor(System.Int32)">
363             <summary>
364             Listen to all network interfaces.
365             </summary>
366             <param name="port">TCP port to listen</param>
367         </member>
368         <member name="M:EasyModbus.TCPHandler.#ctor(System.Net.IPAddress,System.Int32)">
369             <summary>
370             Listen to a specific network interface.
371             </summary>
372             <param name="localIPAddress">IP address of network interface to listen</param>
373             <param name="port">TCP port to listen</param>
374         </member>
375         <member name="T:EasyModbus.ModbusServer">
376             <summary>
377             Modbus TCP Server.
378             </summary>
379         </member>
380         <member name="P:EasyModbus.ModbusServer.LocalIPAddress">
381             <summary>
382             When creating a TCP or UDP socket, the local IP address to attach to.
383             </summary>
384         </member>
385         <member name="P:EasyModbus.ModbusServer.LogFileFilename">
386             <summary>
387             Gets or Sets the Filename for the LogFile
388             </summary>
389         </member>
390         <member name="T:EasyModbus.StoreLogData">
391             <summary>
392             Store Log-Data in a File
393             </summary>
394         </member>
395         <member name="M:EasyModbus.StoreLogData.#ctor">
396             <summary>
397             Private constructor; Ensures the access of the class only via "instance"
398             </summary>
399         </member>
400         <member name="P:EasyModbus.StoreLogData.Instance">
401             <summary>
402             Returns the instance of the class (singleton)
403             </summary>
404             <returns>instance (Singleton)</returns>
405         </member>
406         <member name="M:EasyModbus.StoreLogData.Store(System.String)">
407             <summary>
408             Store message in Log-File
409             </summary>
410             <param name="message">Message to append to the Log-File</param>
411         </member>
412         <member name="M:EasyModbus.StoreLogData.Store(System.String,System.DateTime)">
413             <summary>
414             Store message in Log-File including Timestamp
415             </summary>
416             <param name="message">Message to append to the Log-File</param>
417             <param name="timestamp">Timestamp to add to the same Row</param>
418         </member>
419         <member name="P:EasyModbus.StoreLogData.Filename">
420             <summary>
421             Gets or Sets the Filename to Store Strings in a File
422             </summary>